Quick Answer
PF means the power was interrupted; press Start to resume. L2 means low or no line voltage, so the dryer runs without heat; check the breaker. AF or a Check Vent light means airflow is restricted; clean the lint screen and vent. F3 E1 points to a temperature sensor circuit, and F1 codes point to the main control. Codes vary by model, so check the manual for your model number.
Codes You Can Usually Clear Yourself
PF (power failure). The dryer lost power during a cycle, perhaps from a brief outage or a tripped breaker. Press Start to continue, or clear the display and start again. If PF keeps appearing without an outage, the dryer cord, the outlet or the circuit may have a loose connection, and that needs checking.
AF or Check Vent. The dryer has detected that air is not moving through it properly. Clean the lint screen, check that the duct behind the dryer is not crushed, and make sure the flap on the outside vent hood opens freely. Restricted airflow makes drying slow and makes the dryer run hot, so treat this code as a warning, not a nuisance.
L2: Low or No Line Voltage
An electric dryer uses a 240-volt supply made of two halves. The drum motor only needs one half, so when the other half is missing the dryer keeps turning but the heater will not switch on, and the display can show L2. The most common cause is one side of the double breaker tripping.
- Go to your electrical panel and find the dryer breaker.
- Switch it fully off, then firmly back on, even if it looks fine.
- If your home has fuses, check both fuses for the dryer circuit.
- Run a timed dry cycle with heat and check the drum warms up.
If L2 comes back, stop there. A breaker that keeps tripping, a scorched plug or outlet, or a loose cord connection all need a qualified person. Do not open the electrical panel cover yourself.
| Code | Plain-English meaning | First step |
|---|---|---|
| PF | Power was interrupted during the cycle | Press Start to resume |
| L2 | Low or no line voltage; no heat | Reset the double breaker fully off and on |
| AF / Check Vent | Restricted airflow | Clean the lint screen and check the vent run |
| F3 E1 | Temperature sensor (thermistor) circuit reading open | Unplug for one minute; call if it returns |
| F1 codes | Main control fault | Unplug for one minute; call if it returns |
When a Code Needs a Technician
- F3 or F1 codes that return after unplugging the dryer for a minute.
- L2 that keeps coming back after a breaker reset.
- AF that stays on even with a clean lint screen and vent.
- Any code together with a burning smell or a very hot cabinet.
A technician tests the sensor, wiring or control with a meter to confirm the fault before replacing anything.
F-Series Codes: Sensors and Controls
Codes that start with F come from the dryer’s self-check. F3 E1 means the dryer is reading an open circuit from a temperature sensor, called a thermistor. That can be the sensor itself, a loose connector or a damaged wire. F1 codes relate to the main control board. In both cases, unplug the dryer for one minute to reset the electronics. If the code returns, the part it points to has to be tested.
Because Whirlpool, Maytag and some other brands share the same family of controls, the same codes can appear on more than one brand. The exact list depends on the model, so keep your manual or the model number handy; it is usually on a label inside the door opening.
Codes Are a Starting Point
A code tells you which part of the dryer noticed a problem, not always which part failed. An AF code, for example, can come from a crushed duct behind the machine or from a vent hood clogged outside. If your dryer is also running cold, our guide to a Whirlpool dryer that is not heating goes through the causes in order. When you need a hand, book electric dryer repair in Greater Victoria, or see our Whirlpool appliance repair in Victoria page for washers, fridges and dishwashers too.
Frequently Asked Questions
What does PF mean on a Whirlpool dryer?
PF means the power was interrupted during a cycle. Press Start to resume. If it keeps happening without a power outage, have the cord, outlet and circuit checked for a loose connection.
How do I clear an L2 code on my Whirlpool dryer?
Switch the dryer’s double breaker fully off and back on, or check both fuses, then test a heated cycle. If L2 returns, the circuit or the dryer’s power connection needs checking by a qualified person.
What does AF mean on a Whirlpool dryer?
AF means restricted airflow. Clean the lint screen, check that the duct behind the dryer is not crushed, and make sure the outside vent flap opens. Do not ignore it: poor airflow makes the dryer run hot.
Is F3 E1 a serious fault?
F3 E1 means a temperature sensor circuit is reading open. Unplug the dryer for a minute. If the code comes back, the sensor or its wiring needs testing and usually replacing.